CO2 לייזר
Up to 2,000 characters/sec.(1)
Up to 15m/sec. (49ft/sec.)(1)
Approx. 30.8×38.2mm2 to 601.0×439.8mm2
10.6μm, 10.2μm and 9.3μm
Standard industrial fonts (Type 1 Windows® TrueType®) and Single line fonts
Machine readable codes (OCR, 2D-matrix, etc.)
Bar codes: BC25, BC25i, BC39, BC128, GS1-128, EAN13, UPC_A, RSS14,
RSS14 Truncated, RSS14 Stacked, RSS14 Stacked Omnidirectional, RSS Limited,
RSS Expanded, etc.
Graphics, logos, symbols, etc.
Linear, circular, angular, reverse, rotate
Sequential and batch numbering
Automatic date, layer and time coding; real-time clock
Dot mode enables marking 2D codes faster than traditional grid mode
Sealed CO2 laser, power class 30-Watt
Steered beam with digital high-speed galvanometer scanners
Focal lengths: 64/ 95/ 127/ 190/ 254 mm (2.5/ 3.75/ 5.0/ 7.5/ 10.0 inches);
63.5/ 85/ 100/ 150/ 200/ 300/ 351/ 400 mm (2.50/ 3.35/ 3.94/ 5.9/ 7.87/ 11.8/
13.8/ 15.75 inches); 400/ 500/ 600 mm (15.75/ 19.68/ 23.62 inches)
Handheld controller
PC software
TCS Touch Control Software
CLARiTYTM Laser Controller
Smart Graph Com
Arabic, Bulgarian, Czech, Danish, English, German, Greek, Finnish, French, Hebrew, Hungarian, Italian, Japanese, Korean, Dutch, Norwegian, Polish, Portuguese, Romanian, Russian, Serbian, Simplified Chinese, Slovak, Spanish, Swedish, Thai, Traditional Chinese, Turkish, Vietnamese; interface dependent. Additional languages available with Smart Graph software.
Ethernet, TCP/IP and RS232 optional
Inputs for encoders and product detector triggers
16 inputs / 11 outputs for start/stop signals, machine/operator interlocks, alarm outputs;
in addition to the safety circuits
Customer-specific solutions available
Direct integration into complex production lines via scripting interface
Flexible beam delivery options (beam extension unit/ beam turning unit)
Detachable umbilical for simple integration; available in 3 lengths
100-240 VAC (autorange), ~50/60Hz, 1PH, 0.70KW
Air cooled
Temperature 40-105° F (5-40° C)
Humidity 10%-90%, non-condensing
Supply Unit: IP54, optional IP65
Marking Unit: IP54, optional IP65
Optional safety module provides Performance Level d (PFL-d) in accordance
to EN 13849-1
IEC/EN 60825-1:2014
Supply unit: IP54/IP65 25.4lbs. (11.5kg)
Marking unit: IP54 42.1lbs. (19.1kg); IP65 44.1lbs. (20kg)
CE, TÜV/NRTL, FCC
Compliance (no certification required): ROHS, CDRH/FDA